R&S ZNB Series User Manual page 904

Vector network analyzers
Table of Contents

Advertisement

®
R&S
ZNB/ZNBT
CALCulate:FMODel:EZD<Ph_pt>:COUPon[:STATe] <Boolean>
For a fixture modeling with the EZD tool, this command allows to specify the ports to
which the test coupon is connected.
This has to be defined before measuring the test coupon (using
EZD:COUPon:MEASure).
Suffix:
<Ph_pt>
Parameters:
<Boolean>
Options:
Manual operation:
CALCulate:FMODel:EZD:DCEXtrapolat <Boolean>
Defines whether the Touchstone de-embedding file generated by the EZD tool contains
data for DC.
Parameters:
<Boolean>
Options:
Manual operation:
CALCulate:FMODel:EZD:DUT:MEASure
For a fixture modeling with the EZD tool, this command allows to measure "DUT + Test
Fixture" at the active ports (see CALCulate:FMODel:EZD<Ph_pt>:DUT[:STATe])
Usage:
Options:
Manual operation:
CALCulate:FMODel:EZD:DUT:MEASure:FILename <String>
For a fixture modeling with the EZD tool, this command loads the "DUT + Test Fixture"
properties from a Touchstone file.
User Manual 1173.9163.02 ─ 62
.
Physical port number
ON (1)
if the test coupon is connected to port <Ph_pt>
OFF (0)
otherwise
R&S ZNB/ZNBT-K210
See
"Active"
on page 631
ON (1)
The EZD tool adds (extrapolated) S-parameter data for f = 0.
OFF (0)
The frequencies only reach down to the start frequency of the
instrument sweep.
R&S ZNB/ZNBT-K210
See
"DC Extrapolation"
Event
R&S ZNB/ZNBT-K210
See
"Measure"
on page 632
Command reference
SCPI command reference
CALCulate:FMODel:
on page 640
904