ZNB/ZNBT
If the measured quantity is a ratio, or if it is derived from a ratio, its receiving port is
given as the index of the wave quantity in the numerator. If the active trace shows an
S-parameter S
balanced, then the same offset and length is applied to both its physical ports.
Remote command:
[SENSe<Ch>:]CORRection:LOSS:AUTO
Fixture Compensation...
The "Fixture Compensation..." button opens the
Evaluation Range...
The "Evaluation Range..." button opens the
restrict the frequency range of auto length (and loss) calculations.
5.13.4 Single Ended tab
Allows you to specify 2-port deembedding/embedding networks for each physical port.
Such a network is either defined:
via its S-parameters stored in a two-port Touchstone file (*.s2p) or
by selecting a predefined lumped element model and specifying the available
parameters (resistances/conductances, capacitances, inductances)
See
Use the complementary dock widget to activate or deactivate dembedding/embedding
for selected ports (see
Background information
Refer to the section
on page 219.
User Manual 1173.9163.02 ─ 62
, then "Auto Length" adds a length offset at port i. If the receive port is
ij
Chapter 4.6.2.3, "Circuit models for 2-port
Chapter 5.13.1.3, "Single Ended
Chapter 4.6.2.10, "Combining Several de-/embedding
Offset Embed softtool
Fixture Compensation
Evaluation Range dialog
networks",
on page 210.
panel",
on page 608).