R&S ZNB Series User Manual page 916

Vector network analyzers
Table of Contents

Advertisement

®
R&S
ZNB/ZNBT
Parameters:
<AttenLeadInScaling>
Manual operation:
CALCulate:FMODel:ISD:SCALe:FREQuency <MaxFrequency>
Defines the maximum frequency to deembed.
Corresponds to the max_frequency batch mode parameter of the ISD tool.
Parameters:
<MaxFrequency>
Manual operation:
CALCulate:FMODel:ISD:SCALe:FTIMe <FltLeadInScalingTime>
Overrides the lead-in's flight time in case the through-trace test coupon is a bit too
short or too long.
Sets/gets the atten_scale 1 batch mode parameter of the ISD tool.
Parameters:
<FltLeadInScalingTime>
Manual operation:
CALCulate:FMODel:ISD:SMALlfixture <Boolean>
Enables/disables the ISD tool's small fixture mode.
Parameters:
<Boolean>
Manual operation:
CALCulate:FMODel:ISD:TRACe:COUPling <TraceCoupling>
Tells the ISD tool about coupling among lead-in traces.
Corresponds to the coupling batch mode parameter of the ISD tool.
Parameters:
<TraceCoupling>
Manual operation:
User Manual 1173.9163.02 ─ 62
See
"Scaling for attenuation"
Default unit: Hz
See
"Max Freq to Deembed"
See
"Scaling for flight time"
See
"Small Fixture"
on page 638
NONE | WEAK | STRong
NONE: no coupling.
WEAK: coupling will be extracted even if there are 2 ports
enabled on the test coupon
STRong: if the test coupon is a 4-port file, and there are two
ports to be extracted, the ISD tool will optimize odd- and even-
mode insertion losses
See
"Trace Coupling"
on page 637
Command reference
SCPI command reference
on page 636
on page 638
on page 636
916