Before executing this command, the pattern type must be set to USER (see
CALCulate<Chn>:EYE:INPut:BPATtern:TYPE).
Suffix:
<Chn>
Parameters:
<BitLength>
Options:
Manual operation:
CALCulate<Chn>:EYE:INPut:LENGth:PRBS <PrbsLength>
Defines the length of the pseudo-random binary sequence to be simulated for the rela-
ted eye diagram.
This command will raise an execution error if the active trace in the selected channel is
not an eye diagram.
Before executing this command the pattern type must be set to PRBS (see
CALCulate<Chn>:EYE:INPut:BPATtern:TYPE).
Suffix:
<Chn>
Parameters:
<PrbsLength>
Options:
Manual operation:
CALCulate<Chn>:EYE:INPut:MODulation <PAMType>
Defines or queries the modulation type of the signal to be simulated for the related eye
diagram.
This command will raise an execution error if the active trace in the selected channel is
not an eye diagram.
Suffix:
<Chn>
Parameters:
<PAMType>
Manual operation:
User Manual 1173.9163.02 ─ 62
.
Channel number used to identify the active trace
Stream length, specified with units BITS, KIBITS (2^10 BITS),
MIBITS (2^20 BITS), or GIBITS (2^30 BITS)
Default unit: BITS
R&S ZNB/ZNBT-K20
See
"Length"
on page 693
.
Channel number used to identify the active trace
L5 | L7 | L9 | L10 | L11 | L13 | L15
Li represents an actual sequence length of 2
R&S ZNB/ZNBT-K20
See
"Length"
on page 693
.
Channel number used to identify the active trace
NRZ | PM4 | PM8 | PM16
NRZ, PAM-4, PAM-8 or PAM-16
*RST:
NRZ
See
"Modulation"
on page 693