4.2 Parameter setting procedure
Switching modes:
Power On
Monitoring
mode
Parameter
mode
Alarm mode
Operating in each mode:
Monitoring mode
Refer to Chapter 8.
M
Refer to Chapter 8 for parameters.
1. If no alarm occurs, Alarm mode is skipped.
M
2. When a new alarm occurs, it switches to Alarm mode from
any other mode.
3. When switching to a different mode, if you do not press
a key within 20 seconds, it returns to Alarm mode.
M
See Chapter 14 for detailed alarm information.
Monitoring
mode
Test Operation and Panel Display
1. Press
keys to select monitoring
variables. Refer to Section 4.3.5 for
detailed information.
2. You can directly enter the code of
monitoring variables via P0.002.
Refer to Chapter 8 for a detailed
description of P0.002.
3. Press the SHIFT key to switch the
display of high / low digits of
monitoring variables.
4
4-3