ASDA-A3
P2.021
0x0105 (A3-L, A3-M)
Default:
0x0007 (A3-F, A3-E)
Unit: -
Format: HEX
Settings:
Refer to the description of P2.018.
P2.022
0x0007 (A3-L, A3-M)
Default:
0x0100 (A3-F, A3-E)
Unit: -
Format: HEX
Settings:
Refer to the description of P2.018.
P2.023
Default: 1000
Unit: Hz
Format: DEC
Settings:
The resonance frequency of the first Notch filter. This function is disabled if P2.024 is 0. P2.023, P2.024,
and P2.095 are the first set of Notch filter parameters.
P2.024
Default: 0
Unit: -dB
Format: DEC
Settings:
The attenuation level of the first Notch filter. A value of 5 indicates -5 dB. Set this parameter to 0 to
disable the first Notch filter.
DO4 functional planning
DO5 functional planning
Notch filter 1 - frequency
Notch filter 1 - attenuation level
Control mode: All
Setting range: 0x0000 - 0x014F (last two codes
are DO codes)
Data size: 16-bit
Control mode: All
Setting range: 0x0000 - 0x014F (last two codes
are DO codes)
Data size: 16-bit
Control mode: All
Setting range: 50 to 5000
Data size: 16-bit
Control mode: All
Setting range: 0 to 40
Data size: 16-bit
Parameters
Address: 022AH
022BH
Address: 022CH
022DH
Address: 022EH
022FH
Address: 0230H
0231H