Chapter 4 Panel Display and Operation

4.2 Parameter Setting Procedure

(1) When the servo drive connects to the power, the display will show the monitor variable
for about one second, and then enter into the Monitor Mode.
(2) Press the MODE Key can switch mode from Parameter Mode → Monitor Mode →
Alarm Mode. If no alarm occurs, then the Alarm Mode will be skipped.
(3) When new alarm occurs, it will switch to Alarm Display Mode in any conditions.
Pressing the MODE Key can switch to the other modes. If there is no Key to be
selected for 20 seconds, it will return to the Alarm Mode automatically.
(4) In Monitor Mode, press UP or DOWN Key can switch the monitor variable. The monitor
variable will be displayed for a second.
(5) In Parameter Mode, pressing the SHIFT Key can switch the group code. The
UP/DOWN Key can change parameter code of two bytes.
(6) In Parameter Mode, press the SET Key, the system will immediately enter into Editing
Setting Mode. The display will show the corresponded setting value of the parameter.
The UP/DOWN Key can be used to change the parameter value or press the MODE
Key to skip Editing Setting Mode and return to Parameter Mode.
(7) In Editing Setting Mode, pressing the SHIFT Key can move the blinking bit to the left.
And use the UP/DOWN Key to adjust the higher setting byte value.
(8) After adjusting the setting value, press the SET Key. It can save the parameter or
execute the command.
(9) After finish parameter setting, the display will show the end code 「SAVED」and
return to the Parameter Mode automatically.
4-2
ASDA-B2
Revision May, 2018