ASDA-A3
P2.015
0x0022 (A3-L, A3-M)
Default:
0x0023 (A3-F, A3-E)
Unit: -
Format: HEX
Settings:
Refer to the description of P2.010.
P2.016
0x0023 (A3-L, A3-M)
Default:
0x0021 (A3-F, A3-E)
Unit: -
Format: HEX
Settings:
Refer to the description of P2.010.
P2.017
0x0021 (A3-L, A3-M)
Default:
0x0100 (A3-F, A3-E)
Unit: -
Format: HEX
Settings:
Refer to the description of P2.010.
There is no physical pin for DI8 on A3-F and A3-E models. DI8 is a virtual digital input which you can
use when the number of physical DI points is insufficient or to trigger through communication. You can
set the DI to be used as soon as power is on when the contact would be normally closed for virtual
digital input, such as Servo On.
DI6 functional planning
DI7 functional planning
DI8 functional planning
Control mode: All
Setting range: 0x0000 - 0x015F (last two codes
are DI codes)
Data size: 16-bit
Control mode: All
Setting range: 0x0000 - 0x015F (last two codes
are DI codes)
Data size: 16-bit
Control mode: All
Setting range: 0x0000 - 0x015F (last two codes
are DI codes)
Data size: 16-bit
Parameters
Address: 021EH
021FH
Address: 0220H
0221H
Address: 0222H
0223H