Delta ASDA-A3 Series User Manual page 837

Hide thumbs Also See for ASDA-A3 Series:
Table of Contents

Advertisement

Parameters
PM.028▲●
Default: 10
8
Format: DEC
Settings:
Input the correct value according to the specifications of the third-party permanent-magnet rotary motor.
Note: pole number = pole pair x 2
PM.029▲●
Operation
interface:
Default: -
Setting range:
Format: Two decimals
Example: 1.5 = 1.5 Arms
Settings:
Input the correct value according to the specifications of the third-party permanent-magnet rotary motor.
Unit conversion between Ampere peak and Ampere RMS:
PM.030▲●
Operation
interface:
Default: -
Setting range:
Format: Two decimals
Example: 1.5 = 1.5 Arms
Settings:
Input the correct value according to the specifications of the third-party permanent-magnet rotary motor.
Unit conversion between Ampere peak and Ampere RMS:
8-260
Permanent-magnet rotary motor pole number
Unit: pole
Permanent-magnet rotary motor rated current
Panel / software
Unit: Arms
0.00 to servo drive rated
current
Ampere peak ( Apk ) = Ampere RMS (Arms) × √2
Permanent-magnet rotary motor maximum current
Panel / software
Unit: Arms
0.00 to servo drive
maximum current
Ampere peak ( Apk ) = Ampere RMS (Arms) × √2
Applicable motor: Permanent-magnet rotary motor
Setting range: 2 to 100
Data size: 16-bit
Applicable
Communication
motor:
-
Data size: 16-bit
0.01 Arms
0 to servo drive rated current x 100
DEC
150 = 1.5 Arms
Applicable
Communication
motor:
-
Data size: 16-bit
0.01 Arms
0 to servo drive maximum current x 100
DEC
150 = 1.5 Arms
Address: FD38H
FD39H
Address: FD3AH
FD3BH
Permanent-magnet rotary motor
Address: FD3CH
FD3DH
Permanent-magnet rotary motor
ASDA-A3

Advertisement

Table of Contents
loading

This manual is also suitable for:

A3-lA3-mA3-fA3-e

Table of Contents