Parameters
P5.066
Operation
interface:
8
Default:
Setting range:
Format: DEC
Example:
Settings:
Target speed #6 of PR mode.
Note: rotary means a permanent-magnet synchronous rotary motor; linear means a permanent-magnet synchronous
linear motor.
P5.067
Operation
interface:
Default:
Setting range:
Format: DEC
Example:
Settings:
Target speed #7 of PR mode.
Note: rotary means a permanent-magnet synchronous rotary motor; linear means a permanent-magnet synchronous
linear motor.
8-180
Target speed setting #6
Panel / software
600.0 (rotary)*
600 (linear)*
1 rpm (rotary)*
Unit:
1 μm/s (linear)*
0.0 to 7500.0 (rotary)*
0 to 15999999 (linear)*
1.0 = 1 rpm (rotary)*
1 = 1 μm/s (linear)*
Target speed setting #7
Panel / software
800.0 (rotary)*
800 (linear)*
1 rpm (rotary)*
Unit:
1 μm/s (linear)*
0.0 to 7500.0 (rotary)*
0 to 15999999 (linear)*
1.0 = 1 rpm (rotary)*
1 = 1 μm/s (linear)*
Communication
Control mode: PR
6000
Data size: 32-bit
0.1 rpm (rotary)*
1 μm/s (linear)*
0 to 75000 (rotary)*
0 to 15999999 (linear)*
10 = 1 rpm (rotary)*
1 = 1 μm/s (linear)*
Communication
Control mode: PR
8000
Data size: 32-bit
0.1 rpm (rotary)*
1 μm/s (linear)*
0 to 75000 (rotary)*
0 to 15999999 (linear)*
10 = 1 rpm (rotary)*
1 = 1 μm/s (linear)*
Address: 0584H
0585H
-
-
-
-
Address: 0586H
0587H
-
-
-
-
ASDA-A3