Delta ASDA-A3 Series User Manual page 636

Hide thumbs Also See for ASDA-A3 Series:
Table of Contents

Advertisement

ASDA-A3
P1.023
Default: 0
Unit: Pulse unit of compare source
Format: DEC
Settings:
This parameter sets the shifting amount for the data array to be compared. And the result is the actual
data array for comparison when you use the Compare function.
Example:
If the data array for comparison is DATA_ARRAY[100] = 2000; P1.023 = 40; P1.024 = 0, the actual data
for comparison = 2000 + 40 = 2040.
Note: monitor CMP_DATA with the monitoring variable 037 (25h).
P1.024■
Default: 0
Unit: Pulse unit of compare source
Format: DEC
Settings:
This parameter sets the shifting amount for the data array to be compared. And the result is the actual
data array for comparison when you use the Compare function.
Note:
1.
If P1.019.Z [Bit 0] = 1, this parameter automatically resets after taking effect.
2.
Monitor CMP_DATA with the monitoring variable 037 (25h).
P1.025
Default: 1000
Unit: 0.1 Hz
Format: DEC
Example: 150 = 15 Hz
Settings:
The frequency of the first low-frequency vibration suppression filter. When you set P1.026 to 0, the first
low-frequency vibration suppression filter is disabled.
Compare: data shift (non-volatile)
CMP_DATA = DATA_ARRAY[*] + P1.023 + P1.024
Compare: data shift (reset automatically)
CMP_DATA = DATA_ARRAY[*] + P1.023 + P1.024
Low-frequency vibration suppression frequency 1
Control mode: All
Setting range: -10000000 to +100000000
Data size: 32-bit
Control mode: All
Setting range: -32768 to +32767
Data size: 16-bit
Control mode: PT / PR
Setting range: 10 to 1000
Data size: 16-bit
Parameters
Address: 012EH
012FH
Address: 0130H
0131H
Address: 0132H
0133H
8