ASDA-A3
Wiring
DI wiring - input signals by relay or open collector transistor.
Conditions of DI On / Off:
3
ON: 15V - 24V; condition: input current = 8 mA.
OFF: 5V or below; the input current must not be higher than 0.5 mA.
C7: NPN transistor (SINK mode)
C8: PNP transistor (SOURCE mode)
3-97