ASDA-A3
Value: 0x08
DI name
In PR mode, after the PR command (POS0 - 6) is selected, the motor
CTRG
operates according to the command issued by the register when this DI
is on.
Value: 0x09
DI name
In Speed and Position modes, motor torque is limited when this DI is on,
TRQLM
and source of the Torque limit command is the internal register or
analog voltage.
Value: 0x0A
DI name
When the gantry synchronization function is enabled (P1.074 = 2),
switch this DI on to temporarily disable the monitoring function of the
GTRY
gantry synchronization. After receiving this DI, the servo stops
calculating and monitoring the error between the two axes.
Value: 0x0B
DI name
FHS
Switch between full- and semi-closed loop modes.
Note: PR full-closed loop function is not yet supported.
Value: 0x0C
DI name
Latch function of analog Position command. If this DI is on, the position
of the motor is held at the current position when the DI is triggered.
During this DI is on, the motor does not operate even when there is a
change in the analog command. When this DI is off, the motor
completes the command that was changed during the time DI was on.
VPL
Motor
position
when DI is
triggered
Description
Description
Description
Description
Description
Motor position
(Turn)
Change amount
Voltage
of the analog
when DI is
input command
triggered
during DI is on;
motor does not
move
Triggering
triggered
Triggering
triggered
Triggering
triggered
Triggering
triggered
Triggering
When DI is off, motor
operates to the
corresponding
position of the analog
triggered
voltage input
Analog input
command (V)
Parameters
Control
method
mode
Rising-
edge
PR
Control
method
mode
Level
PT, PR, S
Control
method
mode
Rising-
edge
PT
Control
method
mode
Level
PT, PR*
Control
method
mode
Level
PT
8-267