ASDA-A3
Linear Motor and Third-Party Motor
Encoder / Linear Scale Setting (sine wave type)
11
PM.004 Main encoder resolution: input the corresponding distance for the motor single-phase
sine wave (unit: 0.001 µm/period).
PM.005 Position signal converter box interpolation magnification: it is suggested that you
set it to the default value of 11. After the interpolation, the resolution is PM.004x0.001 / 2
N
, and
N = PM.005.
PM.045 Linear motor pole pitch: you can find this value in the linear motor catalog. If the set
value is incorrect, AL051 is triggered.
When the settings are complete, click Write and then click Next.
Note: the grayed-out field is read-only and cannot be edited.