Wiring
Connect the shielded wires to the CN2 encoder connector as follows:
3
(A)
(C)
3-102
(B)
Step 1:
Strip the cable and expose the wires covered
by the metal shield. The exposed wire length
should be 20 - 30 mm (0.79 - 1.18 inches).
Step 2:
Spread the metal shield and fold it back.
Refer to the pin assignment in the preceding
table to connect the wires.
Step 3:
You need the following items to assemble the
connector:
(A) Big metal case
(B) Small metal case
(C) U-shaped bracket
Step 4:
Place the big metal case to cover the
exposed metal shield. Make sure the metal
shield is completely covered to maintain the
integrity of the shielding.
Step 5:
Fasten the small metal case on the other
side.
Step 6:
Place the U-shaped bracket over the big
metal case and fasten them with screws.
Step 7:
Fit one side of the plastic case over the
connector.
Step 8:
Place and fasten the other side of the case to
complete assembling the connector.