Parameters
Example 1:
8
1.
When the load ratio is 160%, the overload (AL006) protection counter continues to increase.
2.
When the load ratio is 100%, the operating level is leveled off.
3.
When the load ratio is 40%, the overload (AL006) protection counter continues to decrease.
Example 2:
As shown in the preceding figure, the load ratio affects whether the load is accumulated. When the load
accumulates over 100%, the operating time must be taken into consideration, or else AL006 occurs.
8-258
Overload (AL006)
protection counter
100%
0%
Overload (AL006)
protection counter
100%
0%
T1
T1
T2
AL006 occurs
Servo Off
T2
T3
Load ratio
Load ratio
Operating level
160%
100%
40%
Time
T3
Load ratio
Load ratio
Operating level
160%
140%
40%
Time
ASDA-A3

Advertisement