Models: A3-F - Delta ASDA-A3 Series User Manual

Hide thumbs Also See for ASDA-A3 Series:
Table of Contents

Advertisement

ASDA-A3
1.4.7 400V models: A3-F
No.
Name
(1)
-
(2)
CHARGE
(3)
CN4
(4)
CN6
(5)
CN1
(6)
CN2
Grounding
(7)
screws
(8)
CN10
(9)
24V*, 0V*
(10)
RST*
(11)
UVW*
Regenerative
resistor*
(12)
(P3, D, C,
(13)
P1*, P2*
(14)
CN5
Note: the types of terminal blocks with * vary with the models, but this does not affect their pin
assignments and functions.
A Top view
B Bottom view
7-segment display.
Power indicator.
Mini USB connector: connects to PC.
DMCNET high-speed communication port connector.
I/O signal interface: connects to PLC or controls I/O.
Encoder connector: connects to the encoder.
Connects to the ground wire for the power and servo motor.
STO (Safe Torque Off).
Control circuit power input terminal: connects to 24 V
Main circuit power input terminal: connects to commercial power supply
(380 - 480 V
, 50 / 60 Hz).
AC
Servo drive current output: connects to the motor power connector (U, V, W).
Do not connect to the main circuit power. Incorrect wiring will cause damage
to the servo drive.
When an external regenerative resistor is used: P3 and C contacts connect
to the resister; P3 and D contacts are left open.
When the built-in regenerative resistor is used: P3 and C contacts are left
open; P3 and D contacts are short-circuited (connected).
)
When an external regenerative unit is used: P3 and
the regenerative unit; P3 & C contacts and P3 & D contacts are left open.
Coming soon.
Position feedback connector.
A Top view
Description
Product Overview
B Bottom view
±10% power supply
DC
contacts connect to
1