Parameters
PM.048▲
Default: -
8
Format: DEC
Settings:
Input the correct value according to the specifications of the linear motor.
PM.049▲
Operation
interface:
Default: -
Setting range: 0.00 to 1773.62
Format: Two decimals
Example: 1.5 = 1.5 N/Arms
Settings:
Input the correct value according to the specifications of the linear motor.
PM.050▲
Operation
interface:
Default: -
Setting range: 0.000 to 2000.000
Format: Three decimals
Example: 1.5 = 1.5 ohm
Settings:
Input the correct value according to the specifications of the linear motor.
8-264
Linear motor maximum speed
Unit: mm/s
Linear motor force constant
Panel / software
Unit: N/Arms
Linear motor phase resistance
Panel / software
Unit: ohm
Applicable
motor:
Setting range: 0 to 15999
Data size: 16-bit
Applicable
Communication
motor:
-
Data size: 32-bit
0.01 N/Arms
0 to 177362
DEC
150 = 1.5 N/Arms
Applicable
Communication
motor:
-
Data size: 32-bit
0.001 ohm
0 to 2000000
DEC
1500 = 1.5 ohm
Address: FD60H
FD61H
Linear motor
Address: FD62H
FD63H
Linear motor
Address: FD64H
FD65H
Linear motor
ASDA-A3