Delta ASDA-A3 Series User Manual page 734

Hide thumbs Also See for ASDA-A3 Series:
Table of Contents

Advertisement

ASDA-A3
P4.022
Default: 0
Unit: mV
Format: DEC
Settings:
Manually adjust the compensation value for the offset.
P4.023
Default: 0
Unit: mV
Format: DEC
Settings:
Manually adjust the compensation value for the offset.
P4.024
160 (220V models)
Default:
282 (400V models)
Unit: V (rms)
Format: DEC
Settings:
When the voltage of the DC Bus is lower than P4.024 x
P4.025 -
P4.026
P4.027
Default: 200
Unit: ms
Format: DEC
Settings:
This parameter is used to adjust the time duration before the STO internal circuit diagnosis is performed
to avoid misdetection and triggering AL503.
P4.028 -
P4.043
Analog speed input - offset compensation value
Analog torque input - offset compensation value
Level of undervoltage error
Reserved
AL503 diagnosis time (220V models)
Reserved
Control mode: S
Setting range: -5000 to +5000
Data size: 16-bit
Control mode: T
Setting range: -5000 to +5000
Data size: 16-bit
Control mode: All
Setting range: 140 to 380
Data size: 16-bit
, the undervoltage alarm (AL003) occurs.
Control mode: All
Setting range: 1 to 500
Data size: 16-bit
Parameters
Address: 042CH
042DH
Address: 042EH
042FH
Address: 0430H
0431H
Address: 0436H
0437H
8
8-157