Delta ASDA-A3 Series User Manual page 125

Hide thumbs Also See for ASDA-A3 Series:
Table of Contents

Advertisement

Wiring
Motor frame: F100 - F130
3
Power
cable
Brake
cable
Max. wiring length
Standard length provided
Note:
Refer to Sections 3.1.6.1 and 3.2.6.1.
1.
Apart from the specifications mentioned above, refer to Section 2.7.1 for the motor cable selection and
2.
installation precautions.
3-44
Item
Model name
UL2586 (Temp. rating: 105°C / 221°F)
AWG#16-4C (1.3 mm²)
Specification
Insulator outer diameter: Φ3.2 mm
Model name
UL2586 (Temp. rating: 105°C / 221°F)
AWG#14-4C (2.1 mm²)
Specification
Insulator outer diameter: Φ2.8 mm
Model name
UL2517 (Temp. rating: 105°C / 221°F)
AWG#20-2C (0.5 mm²)
Specification
Insulator outer diameter: Φ1.8 mm
by Delta
Standard cable
ACS3-CAPWA2XX
ACS3-CRPWA2XX
Test voltage 600 V
AC
ACS3-CAPWA3XX
ACS3-CRPWA3XX
Test voltage 600 V
AC
ACS3-CABRA1XX
ACS3-CRBRA1XX
Test voltage 300 V
AC
L = 3 m, 5 m, 10 m, 20 m
Flexible cable
ACS3-CAPFA2XX
ACS3-CRPFA2XX
UL2586 (Temp. rating: 105°C / 221°F)
AWG#16-4C (1.3 mm²)
Insulator outer diameter: Φ3.2 mm
Test voltage 600 V
ACS3-CAPFA3XX
ACS3-CRPFA3XX
UL2586 (Temp. rating: 105°C / 221°F)
AWG#14-4C (2.1 mm²)
Insulator outer diameter: Φ2.8 mm
Test voltage 600 V
ACS3-CABFA1XX
ACS3-CRBFA1XX
UL2517 (Temp. rating: 105°C / 221°F)
AWG#20-2C (0.5 mm²)
Insulator outer diameter: Φ1.8 mm
Test voltage 300 V
20 m
ASDA-A3
AC
AC
AC

Advertisement