11.6.2 Interface of position signal converter box

No.
Connector for
(1)
signal source
(2)
Status indicator
(3)
Function indicator
Signal switch
(4)
knob
Connector for
(5)
connecting to the
servo drive
(6)
Function switch
Note: the indicators of ERROR and WARNING are irrelevant to the servo alarms; they are for the signal
converter box only.
(1)
ERROR
(2)
WARNING
RUN
X1
X2
X3
X4
X5
(3)
X6
X7
Drive Mode
Switch Mode
Hall S ensor
W/O Hall S ensor
Reserve
Reserve
(4)
(5)
Item
CN26
26-pin connector.
ERROR*
Alarm indicator.
WARNING*
Warning indicator.
RUN
Normal operation indicator.
Displays according to the status of the signal switch
LED
knob (4) and function switch (6).
X1
Square wave digital signal as the source.
X2
Sine wave analog signal as the source.
X3 - X9
Function not supported.
CN20
20-pin connector.
The converter box status is controlled by the
Drive Mode
commands from the servo drive; meanwhile, the signal
switch knob (4) and the function switch (6) are invalid.
The converter box status is controlled by the signal
switch knob (4) and the function switch (6) on the
Switch Mode
converter box; meanwhile, the commands from the
servo drive are invalid.
Hall Sensor
With a Hall sensor installed.
W/O Hall Sensor
Without a Hall sensor installed.
Linear Motor and Third-Party Motor
X1:A,B P ulse
X2:A-Sin B-Cos
X3:
Reserve
X4:
Reserve
X5:
Reserve
X6:Reserve
X7:Reserve
Drive Mode
Hall Sensor
(6)
W O Hall Sensor
/
Switch Mode
Description