As mentioned in Section 7.1.2, the PR mode provides four monitoring variables for you to
monitor the servo commands and feedback status. These are Command position PUU
(Cmd_O), PR command end register (Cmd_E), Feedback position PUU (Fb_PUU), and Position
error PUU (Err_PUU). Before homing completes, the command end register (Cmd_E) cannot be
7
calculated because the coordinate system can only be created after homing is complete, and
the target position remains unknown after the Homing command is issued. This is why the
status of each monitoring variable is different during homing. In Homing command's default
setting, the contents of Cmd_E and Cmd_O are identical. After the servo finds the reference
origin and creates the coordinate system, it sets the content of Cmd_E to the coordinate of the
reference origin. However, once it finds the reference origin, it still requires some distance for
motor to decelerate to a stop. Meanwhile, Cmd_O continues to issue commands. If no other PR
commands are issued after homing (other than the Position command), the contents of the final
command position (Cmd_O) and command end position (Cmd_E) will be different. See Figure
7.1.3.1.3.
command
command
Command in
Command
completed
positioned
7-22
Err_PUU
Before
Fb_PUU
Cmd_O
issued
Cmd_E
Err_PUU
After
Fb_PUU
Cmd_O
issued
Cmd_E
execution
Motor
Figure 7.1.3.1.3 Homing mode and monitoring variables
Err_PUU
Fb_PUU
Cmd_O
Cmd_E
Err_PUU
Fb_PUU
Cmd_O
Cmd_E
Err_PUU
Fb_PUU
Cmd_O
Cmd_E
ASDA-A3