ASDA-A3
P5.038■
Default: 1
Unit: -
Format: DEC
Settings:
When Capture is not in operation, this parameter indicates the number of data sets expected to be
captured (readable and writable). When Capture is in operation, this parameter indicates the remaining
number of data sets to be captured (read-only). Each time one data is captured, the value of P5.038
decrements by 1 until the value is 0, indicating that capturing is complete.
Note: the total number of data sets from Compare, Capture, and E-Cam cannot exceed 800.
P5.039■
Default: 0x2010
Unit: -
Format: HEX
Settings:
U
Z
Y
X
Capture setting
Y
Axis source of Capture
X: Capture setting
Bit
Function
0
Activate Capture
1
Reset position
2
Activate Compare
3
Execute PR
Y: axis source of Capture
0: Capture is not working
1: CN5
2: CN1 (pulse command)
3: CN2
Note: when the source of Compare is the Capture axis, the source of Capture (P5.039.Y) cannot be changed.
Z: trigger logic
0: NO (normally open)
1: NC (normally closed)
Capture: number of capturing times
Capture: activate CAP control
X
Z
U
Start capturing; after capturing is complete, set this bit to 0 automatically (Capture
disabled).
After capturing the first data, reset the position of the first data. The position of the
reset point is set by P5.076.
After capturing the first data, activate Compare, but this setting is invalid if Compare
is already activated.
Execute PR#50 automatically after capturing is complete.
Control mode: All
1 to (value set by P5.010 minus
Setting range:
value set by P5.036)
Data size: 16-bit
Control mode: All
Setting range: 0x0000 - 0xF13F
Data size: 16-bit
Trigger logic
Minimum interval between
each trigger
Description
Parameters
Address: 054CH
054DH
Address: 054EH
054FH
8
8-171