Parameters
P2.097
Default: 5
8
Format: DEC
Settings:
The resonance Q factor of the third Notch filter. This function is disabled if P2.046 is 0. P2.045, P2.046,
and P2.097 are the third set of Notch filter parameters.
P2.098
Default: 1000
Format: DEC
Settings:
The resonance frequency of the fourth Notch filter. This function is disabled if P2.099 is 0. P2.098,
P2.099, and P2.100 are the fourth set of Notch filter parameters.
P2.099
Default: 0
Format: DEC
Settings:
The attenuation level of the fourth Notch filter. A value of 5 indicates -5 dB. Set this parameter to 0 to
disable the fourth Notch filter.
P2.100
Default: 5
Format: DEC
Settings:
The resonance Q factor of the fourth Notch filter. This function is disabled if P2.099 is 0. P2.098, P2.099,
and P2.100 are the fourth set of Notch filter parameters.
8-132
Notch filter 3 - Q factor
Unit: -
Notch filter 4 - frequency
Unit: Hz
Notch filter 4 - attenuation level
Unit: -dB
Notch filter 4 - Q factor
Unit: -
Control mode: All
Setting range: 1 to 10
Data size: 16-bit
Control mode: All
Setting range: 50 to 5000
Data size: 16-bit
Control mode: All
Setting range: 0 to 40
Data size: 16-bit
Control mode: All
Setting range: 1 to 10
Data size: 16-bit
ASDA-A3
Address: 02C2H
02C3H
Address: 02C4H
02C5H
Address: 02C6H
02C7H
Address: 02C8H
02C9H