Parameters
Value: 0x41
DO name
MAG_OK
8
Value: when DI.ABSE is on, DO.ABSR triggered by DO2 will replace the DO2 assigned by P2.019
DO name
ABSR always
output by DO2
Value: when DI.ABSE is on, DO.ABSD triggered by DO3 will replace the DO3 assigned by P2.020
DO name
ABSD always
output by DO3
8-280
Initial magnetic field detection is complete.
When DO.ABSR is off, it indicates servo drive can receive request
issued by DI.ABSQ; when DO.ABSR is on, it indicates after the
request is received, the data has been prepared and the ABSD
data is valid so that the controller can access the ABSD data. This
output is only valid when DI.ABSE is on. Refer to Figure
10.3.5.1.1 for a detailed description.
The DO for ABS data. The data is valid when DO.ABSR is on.
This output is only valid when DI.ABSE is on. Refer to Figure
10.3.5.1.1 for a detailed description.
Description
Description
Description
ASDA-A3
Triggering
Control
method
mode
Level
All
triggered
Triggering
Control
method
mode
Level
All
triggered
Triggering
Control
method
mode
Level
All
triggered