Parameters
P0.060
Default: 0
8
Format: DEC
Settings:
Before using this function, set the digital output function to 0x2F (fourth set of general range
comparison) and the monitoring item of P0.020.
When the monitoring item value of P0.012 is within the range set in P0.060 and P0.061, and after the
filter time set by P0.053.U, this digital output is on.
P0.061
Default: 0
Format: DEC
Settings:
Refer to the description of P0.060.
P0.062
P0.063★
Default: 0
Format: DEC
Settings:
220V models: records the total time during which the voltage of the DC Bus exceeded 400V.
400V models: records the total time during which the voltage of the DC Bus exceeded 800V.
P0.064 -
P0.078
8-40
General range compare digital output 4 - lower limit
Unit: -
General range compare digital output 4 - upper limit
Unit: -
Reserved
Total duration of DC Bus voltage exceeding 400V or 800V
Unit: ms
Reserved
Control mode: All
Setting range: -2147483648 to +2147483647
Data size: 32-bit
Control mode: All
Setting range: -2147483648 to +2147483647
Data size: 32-bit
Control mode: All
Setting range: 0 - 2147483647
Data size: 32-bit
ASDA-A3
Address: 0079H
007AH
Address: 007BH
007CH
Address: 007EH
007FH