Parameters
PM.035▲
Operation
interface:
Default: -
8
Setting range: 0.000 to 2000.000
Format: Three decimals
Example: 1.5 = 1.5 ohm
Settings:
Input the correct value according to the specifications of the third-party permanent-magnet rotary motor.
PM.036▲
Operation
interface:
Default: -
Setting range: 0.00 to 1000.00
Format: Two decimals
Example: 1.5 = 1.5 mH
Settings:
Input the correct value according to the specifications of the third-party permanent-magnet rotary motor.
PM.037
PM.038▲
Operation
interface:
Default: -
Setting range: 0.0000 to 2.2876
Format: Four decimals
Example: 1.5 = 1.5 Vrms/rpm
Settings:
Input the correct value according to the specifications of the third-party permanent-magnet rotary motor.
PM.039 -
PM.044
8-262
Permanent-magnet rotary motor phase resistance
Panel / software
Unit: ohm
Permanent-magnet rotary motor phase inductance
Panel / software
Unit: mH
Reserved
Permanent-magnet rotary motor back electromotive force
constant
Panel / software
Unit: Vrms/rpm
Reserved
Applicable
Communication
motor:
-
Data size: 32-bit
0.001 ohm
0 to 2000000
DEC
1500 = 1.5 ohm
Applicable
Communication
motor:
-
Data size: 32-bit
0.01 mH
0 to 100000
DEC
150 = 1.5 mH
Applicable
Communication
motor:
-
Data size: 32-bit
0.0001 Vrms/rpm
0 to 22876
DEC
15000 = 1.5 Vrms/rpm
Address: FD46H
FD47H
Permanent-magnet rotary motor
Address: FD48H
FD49H
Permanent-magnet rotary motor
Address: FD4CH
FD4DH
Permanent-magnet rotary motor
ASDA-A3

Advertisement

Table of Contents
loading

This manual is also suitable for:

A3-lA3-mA3-fA3-e

Table of Contents