Parameters
P1.094
Default: 10
8
Format: DEC
Settings:
Attenuation rate for the second set of low frequency vibration elimination.
P1.095 -
P1.096
P1.097▲
Default: 0
Format: DEC
Settings:
1.
When P1.074.Y = 0 (output source is from the encoder connected to CN2):
2.
When P1.074.Y = 1 (output source is from the encoder connected to CN5):
3.
When P1.074.Y = 2 (output source is the pulse command from CN1):
8-88
Vibration elimination 2 - resonance difference
Unit: 0.1 dB
Reserved
Encoder output denominator (OA, OB)
Unit: -
When P1.097 = 0, OA / OB pulse output refers to the setting of P1.046. (Refer to Example
1.)
When P1.097 ≠ 0, OA / OB pulse output refers to the settings of P1.046 and P1.097. (Refer
to Example 2.)
When P1.097 = 0, OA / OB pulse output does not refer to the setting of P1.046, but outputs
according to the ratio of 1 : 1 instead.
When P1.097 ≠ 0:
(a) Main encoder is connected to CN5 (PM.003.U = 1): OA / OB pulse output refers to the
settings of P1.046 and P1.097. (Refer to Example 2.)
(b) Main encoder is connected to CN2 (PM.003.U = 0): OA / OB pulse output refers to the
settings of P1.046 and P1.097. (Refer to Example 3.)
When P1.097 = 0, OA / OB pulse output does not refer to the setting of P1.046, but outputs
according to the ratio of 1 : 1 instead.
When P1.097 ≠ 0, OA / OB pulse output refers to the settings of P1.046 and P1.097. (Refer
to Example 4.)
Control mode: PT / PR
Setting range: 10 to 4000
Data size: 16-bit
Control mode: All
Setting range: 0 to 160000
Data size: 32-bit
ASDA-A3
Address: 01BCH
01BDH
Address: 01C2H
01C3H

Advertisement

Table of Contents
loading

This manual is also suitable for:

A3-lA3-mA3-fA3-e

Table of Contents