Frame-Relay Lmi-N391Dce Command - ADTRAN 5000 Series Command Reference Manual

Adtran network device command reference guide
Table of Contents

Advertisement

Command Reference Guide
frame-relay lmi-n391dce <polls>
Use the frame-relay lmi-n391dce command to set the N391 full status polling counter for the DCE
endpoint. Typical applications should leave the default value for this timer. Use the no form of this
command to return to the default value.
Syntax Description
<polls>
Default Values
By default, the polling counter for the DCE endpoint is set to six polls.
Applicable Platforms
This command applies to the NetVanta 1000R, 3000, 4000, and 5000 and Total Access 900 Series units.
Command History
Release 1.1
Functional Notes
The N391 counter determines how many link integrity polls occur in between full status polls. The number
of link integrity polls between full status polls is n - 1, where n represents the full status poll. n can be set to
any number between 1 and 255, but the default is used for most applications.
Usage Examples
The following example sets the N391 counter for three polls:
(config)#interface frame-relay 1
(config-fr 1)#frame-relay lmi-n391dce 3
61200990L1-35E
Sets the counter value (valid range: 1 to 255).
Command was introduced.