Global Configuration Mode Command Set
Usage Examples
The following example sets the LLDP minimum transmit interval to 10 seconds:
(config)#lldp minimum-transmit-interval 10
The following example sets the LLDP reinitialization delay to 5 seconds:
(config)#lldp reinitialization-delay 5
The following example sets the LLDP transmit interval to 15 seconds:
(config)#lldp transmit-interval 15
The following example sets the LLDP TTL multiplier to 2 and the time-to-live for all LLDP frames
transmitted from this unit to 30 seconds;
(config)#lldp transmit-interval 15
(config)#lldp ttl-multiplier 2