frame-relay lmi-n392dte <threshold>
Use the frame-relay lmi-n392dte command to set the N392 error threshold for the DTE endpoint. Typical
applications should leave the default value for this setting. Use the no form of this command to return to
the default value.
Syntax Description
<threshold>
Default Values
By default, the error threshold for the DTE endpoint is set to three errors.
Applicable Platforms
This command applies to the NetVanta 1000R, 3000, 4000, and 5000 and Total Access 900 Series units.
Command History
Release 1.1
Functional Notes
If the error threshold is met, the signaling state status is changed to down, indicating a service-affecting
condition. This condition is cleared once N393 consecutive error-free events are received. N392 defines
the number of errors required in a given event window, while N393 defines the number of polling events in
each window.
For example:
If N392 = 3 and N393 = 4, then if three errors occur within any four events, the interface is determined
inactive.