Frame Relay Sub-Interface Config Command Set
dial-backup shutdown
Use the dial-backup shutdown command to deactivate all dial-backup functionality in the unit.
Dial-backup configuration parameters are kept intact, but the unit will not initiate (or respond) to
dial-backup sequences in the event of a network outage. Use the no form of this command to reactivate the
dial-backup interface. For more detailed information on Frame Relay dial-backup functionality, refer to the
Functional Notes and Technology Review sections of dial-backup call-mode [answer | answer-always |
originate | originate-answer | originate-answer-always]
on page
725.
Syntax Description
No subcommands.
Default Values
By default, all AOS interfaces are disabled.
Applicable Platforms
This command applies to the NetVanta 1000R, 3000, 4000, and 5000 Series units.
Command History
Release 1.1
Command was introduced.
Usage Examples
The following example deactivates the configured dial-backup interface:
(config)#interface frame-relay 1.16
(config-fr 1.16)#dial-backup shutdown