hold-queue <queue size> out
Use the hold-queue out command to change the overall size of an interface's WAN output queue.
Syntax Description
<queue size>
Default Values
The default queue size for WFQ is 400. The default queue size for PPP FIFO and Frame Relay
round-robin is 200.
Applicable Platforms
This command applies to the NetVanta 300, 1000R, 2000, 3000, 4000, and 5000 and Total Access 900
Series units.
Command History
Release 5.1
Usage Examples
The following example sets the overall output queue size to 700:
(config)#interface ppp 1
(config-ppp 1)#hold-queue 700 out
61200990L1-35E
Specifies the total number of packets the output queue can contain before packets
are dropped. Range 16 to 1000.
Command was introduced.
Copyright © 2005 ADTRAN
PPP Interface Configuration Command Set