remote-alarm [rai]
The remote-alarm command selects the alarm signaling type to be sent when a loss of frame is detected
on the T1 receive signal. Use the no form of this command to disable all transmitted alarms.
Syntax Description
rai
Default Values
The default for this command is rai.
Applicable Platforms
This command applies to the NetVanta 1000R, 3000, 4000, and 5000 and Total Access 900 Series units.
Command History
Release 7.1
Usage Examples
The following example enables transmission of RAI in response to a loss of frame:
(config)#interface t1 1/1
(config-t1 1/1)#remote-alarm rai
61200990L1-35E
Specifies sending a remote alarm indication (RAI) in response to a loss of frame.
Also prevents a received RAI from causing a change in interface operational
status.
Command was expanded to include the T1 interface.
Copyright © 2005 ADTRAN
T1 Interface Configuration Command Set
612