connect-sequence interface-recovery [retry-interval <seconds> |
max-retries <value>]
Use the connect-sequence interface-recovery command to allow the interface to go down in the event
that the connect-sequence attempts value is exhausted. Refer to connect-sequence attempts <value>
page 643
for more information. Use the no form of this command to restore the default values.
Syntax Description
retry-interval <seconds> Optional. Specifies the number of seconds the interface will wait between
max-retries <value>
Default Values
By default, the connect-sequence interface-recovery retry-interval is set to 120 seconds and
max-retries are unlimited.
Applicable Platforms
This command applies to the NetVanta 1000R, 3000, 4000, and 5000 Series units.
Command History
Release 11.1
Usage Examples
The following example configures demand interface 1 to wait 60 seconds between retry attempts with a
maximum number of 500 retries:
(config)#interface demand 1
(config-demand 1)#connect-sequence interface-recovery retry-interval 60 max-retries 500
61200990L1-35E
connect sequence cycles during recovery attempts.
Optional. Specifies the maximum number of times the connect sequence will
cycle in an attempt to bring the interface back up. When in interface recovery
mode, this value overrides the connect-sequence attempts value.
Command was introduced.
Copyright © 2005 ADTRAN
Demand Interface Configuration Command Set