E1 Interface Configuration Command Set
loopback remote v54
The loopback remote v54 command initiates an E1 remote loopback test (with a V.54 loopback pattern).
Use the no form of this command to disable this feature.
Syntax Description
No subcommands.
Default Values
No default value is necessary for this command.
Applicable Platforms
This command applies to the NetVanta 1000R, 3000, 4000, and 5000 Series units.
Command History
Release 6.1
Command was introduced.
Functional Notes
This command causes a V.54 inband loop code to be sent in the payload towards the far end.
Usage Examples
The following example sends a V.54 inband loop code to the far end:
(config)#interface e1 1/1
(config-e1 1/1)#loopback remote v54