Dial-Backup Connect-Timeout Command - ADTRAN 5000 Series Command Reference Manual

Adtran network device command reference guide
Table of Contents

Advertisement

Command Reference Guide
dial-backup connect-timeout <seconds>
Use the dial-backup connect-timeout command to specify the number of seconds to wait for a connection
after a call is attempted before trying to call again or dialing a different number. It is recommended this
number be greater than 60. For more detailed information on Frame Relay dial-backup functionality, refer
to the Functional Notes and Technology Review sections of dial-backup call-mode [answer |
answer-always | originate | originate-answer | originate-answer-always]
Syntax Description
<seconds>
Default Values
By default, the dial-backup connect-timeout period is set to 60 seconds.
Applicable Platforms
This command applies to the NetVanta 1000R, 3000, 4000, and 5000 Series units.
Command History
Release 1.1
Usage Examples
The following example configures the AOS to wait 120 seconds before retrying a failed dial-backup call:
(config)#interface frame-relay 1.16
(config-fr 1.16)#dial-backup connect-timeout 120
61200990L1-35E
Selects the amount of time (in seconds) that the router will wait for a connection
before attempting another call (valid range: 10 to 300).
Command was introduced.
Copyright © 2005 ADTRAN
Frame Relay Sub-Interface Config Command Set
on page
725.