10.19 E3-01 [Motor 2 Control Mode] Dependent Parameters
The parameters listed in the following table have a dependent relationship with E3-01. The values of the default
settings change as the setting of E3-01 is changed.
No.
Name
Motor 2 Slip
C3-21
Compensation Gain 0.0 to 2.50
Motor 2 Slip Comp
C3-22
DelayTime
Motor 2 ASR
C5-21
Proportional Gain 1
(P)
Motor 2 ASR
C5-22
Integral Time 1 (I)
Motor 2 ASR
C5-23
Proportional Gain 2
(P)
Motor 2 ASR
C5-24
Integral Time 2 (I)
Motor 2 ASR
C5-26
Delay Time
Motor 2 Maximum
E3-04
Output Frequency
Motor 2 Maximum
E3-05
Output Voltage
Motor 2 Base
E3-06
Frequency
Motor 2 Mid Point
E3-07
A Frequency
Motor 2 Mid Point
E3-08
A Voltage
Motor 2 Minimum
E3-09
Output Frequency
Motor 2 Minimum
E3-10
Output Voltage
Motor 2 Mid Point
E3-11
B Frequency
Motor 2 Mid Point
E3-12
B Voltage
Motor 2 Base
E3-13
Voltage
*1
This is the value for 200 V class drives. Double the value for 400 V class drives.
YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manual
10.19 E3-01 [Motor 2 Control Mode] Dependent Parameters
Setting
Unit
Range
0.1
0 to 10000
1 ms
0.00 to 300.00
0.01
0.000 to 10.000
0.001 s
0.00 to 300.00
0.01
0.000 to 10.000
0.001 s
0.000 to 0.500
0.001 s
40.0 to 590.0
0.1 Hz
0.0 to 255.0
0.1 V
*1
0.0 to 590.0
0.1 Hz
0.0 to 590.0
0.1 Hz
0.0 to 255.0
0.1 V
*1
0.0 to 590.0
0.1 Hz
0.0 to 255.0
0.1 V
*1
Determined
0.0 to 590.0
by o1-04
0.0 to 255.0
0.1 V
*1
0.0 to 255.0
0.1 V
*1
Motor 2 Control Method (setting value of E3-01)
V/f
CL-V/f
(0)
(1)
0.0
-
2000
-
-
0.20
-
0.200
-
0.02
-
0.050
-
-
60.0
60.0
200.0
200.0
60.0
60.0
3.0
3.0
15.0
15.0
1.5
1.5
9.0
9.0
0.0
0.0
0.0
0.0
0.0
0.0
OLV
CLV
(2)
(3)
1.0
1.0
200
-
-
20.00
-
0.500
-
20.00
-
0.500
-
0.004
60.0
60.0
200.0
200.0
60.0
60.0
3.0
0.0
11.0
0.0
0.5
0.0
2.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
517
10