YASKAWA GA700 Technical Manual page 469

High performance type; 200 v class: 0.4 to 110 kw; 400 v class: 0.4 to 355 kw
Hide thumbs Also See for GA700:
Table of Contents

Advertisement

No.
Name
(Hex.)
L3-06
Stall Prevent Level
during Run
(0494)
L3-11
OV Suppression
Function Select
(04C7)
L3-17
DC Bus Reg Level
(0462)
L3-20
DC Bus Voltage
Adjustment Gain
(0465)
L3-21
Accel/Decel Rate
Calculate Gain
(0466)
L3-22
DecTime
atStallPrevent
(04F9)
duringAcc
L3-23
CHP Stall P
Selection
(04FD)
L3-24
Motor Accel Time
for Inertia Cal
(046E)
L3-25
Load Inertia Ratio
(046F)
L3-26
Additional DC Bus
Capacitors
(0455)
L3-27
Stall Prevention
Detection Time
(0456)
L3-34
Torque Limit
Delay Time
(016F)
L3-35
IntDecSp
dAgrWdth
(0747)
L3-36
VibraSuppression
Gain duringAccel
(11D0)
YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manual
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the current level to trigger Stall Prevention during run. A
setting of 100% is equal to the drive rated current.
Note:
• This parameter is valid if L3-05 = 1, 2 [Stall Prevent Select
during Run = Decel time 1, Decel time 2].
• The upper limit and default for this setting is determined by C6-
01 [Normal / Heavy Duty Selection] and L8-38 [Carrier
Frequency Reduction].
V/f
CL-V/f
OLV
CLV
AOLV
Enables or disables the overvoltage suppression function.
0 : Disabled
1 : Enabled
V/f
CL-V/f
OLV
CLV
AOLV
Set the target value for the DC bus voltage used when the
overvoltage suppression function and the Decel Stall Prevention
function (Intelligent Stall Prevention) are running.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the proportional gain used to control the DC bus voltage.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the proportional gain used to calculate acceleration and
deceleration rates.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the brief deceleration time used when stalling occurs while
accelerating a PM motor. This function is valid when L3-01 = 1
[Stall Prevent Select duringAccel = General Purpose].
V/f
CL-V/f
OLV
CLV
AOLV
Selects whether to automatically diminish the Stall Prevent Level
during Run for constant output ranges.
0 : Level set in L3-06
1 : Automatic Reduction
V/f
CL-V/f
OLV
CLV
AOLV
Sets the motor acceleration time taken to reach the maximum
frequency at the motor rated torque for single drive motors that are
stopped.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the ratio between motor inertia and machine inertia.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the capacity for external main circuit capacitors. Normally
there is no need to change this setting. Set this parameter when
using the KEB Ride-Thru function.
V/f
CL-V/f
OLV
CLV
AOLV
Sets a delay time from when the Stall Prevention level is reached
and the actual Stall Prevention function is activated.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the filter time constant in units of seconds used to return the
torque limit to its original value while the KEB operation is
executing under Single Drive KEB Ride-Thru mode.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the width for speed agreement when L3-04 = 2 [Decel Stall
Prevention Selection = Automatic Decel Reduction]. Normally there
is no need to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the gain used to suppress current or motor speed hunting during
operation when L3-01 = 3 [Stall Prevent Select during Accel = ILim
Mode]. Normally there is no need to change this setting.
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
10.11 L: Protection Function
Default
Ref.
(Range)
Determined by C6-
848
01 and L8-38
(30 - 150%)
0
848
(0, 1)
200 V Class: 375
849
V, 400 V Class:
750 V
(200 V Class: 150 -
400 V, 400 V
Class: 300 - 800 V)
Determined by A1-
849
02
(0.00 - 5.00)
Determined by A1-
849
02
(0.10 - 10.00)
0.0 s
850
(0.0 - 6000.0 s)
0
850
(0, 1)
Determined by o2-
850
04, C6-01, E2-11,
and E5-01
(0.001 - 10.000 s)
1.0
851
(1.0 - 1000.0)
0 μF
851
(0 to 65000 μF)
50 ms
851
(0 - 5000 ms)
Determined by A1-
851
02
(0.000 - 1.000 s)
0.00 Hz
852
(0.00 - 1.00 Hz)
Determined by A1-
852
02
(0.0 - 100.0)
10
469