F5: Digital Output Option - YASKAWA GA700 Technical Manual

High performance type; 200 v class: 0.4 to 110 kw; 400 v class: 0.4 to 355 kw
Hide thumbs Also See for GA700:
Table of Contents

Advertisement

10.9 F: Options

F5: Digital Output Option

No.
Name
(Hex.)
F5-01
Terminal P1-PC
Output Selection
(0399)
F5-02
Terminal P2-PC
Output Selection
(039A)
F5-03
Terminal P3-PC
Output Selection
(039B)
F5-04
Terminal P4-PC
Output Selection
(039C)
F5-05
Terminal P5-PC
Output Selection
(039D)
F5-06
Terminal P6-PC
Output Selection
(039E)
F5-07
Terminal M1-M2
Output Selection
(039F)
F5-08
Terminal M3-M4
Output Selection
(03A0)
F5-09
DO-A3 Output
Mode Selection
(03A1)
434
Description
V/f
CL-V/f
OLV
CLV
AOLV
The function output from terminal P1-PC on the DO-A3 card is
selected by the MFDO setting value. This parameter is enabled
when F5-09 = 2 [DO-A3 Output Mode Selection = 8 channel select
(F5-01 to F5-08)].
V/f
CL-V/f
OLV
CLV
AOLV
The function output from terminal P2-PC on the DO-A3 card is
selected by the MFDO setting value. This parameter is enabled
when F5-09 = 2 [DO-A3 Output Mode Selection = 8 channel select
(F5-01 to F5-08)].
V/f
CL-V/f
OLV
CLV
AOLV
The function output from terminal P3-PC on the DO-A3 card is
selected by the MFDO setting value. This parameter is enabled
when F5-09 = 2 [DO-A3 Output Mode Selection = 8 channel select
(F5-01 to F5-08)].
V/f
CL-V/f
OLV
CLV
AOLV
The function output from terminal P4-PC on the DO-A3 card is
selected by the MFDO setting value. This parameter is enabled
when F5-09 = 2 [DO-A3 Output Mode Selection = 8 channel select
(F5-01 to F5-08)].
V/f
CL-V/f
OLV
CLV
AOLV
The function output from terminal P5-PC on the DO-A3 card is
selected by the MFDO setting value. This parameter is enabled
when F5-09 = 2 [DO-A3 Output Mode Selection = 8 channel select
(F5-01 to F5-08)].
V/f
CL-V/f
OLV
CLV
AOLV
The function output from terminal P6-PC on the DO-A3 card is
selected by the MFDO setting value. This parameter is enabled
when F5-09 = 2 [DO-A3 Output Mode Selection = 8 channel select
(F5-01 to F5-08)].
V/f
CL-V/f
OLV
CLV
AOLV
Selects the function output from terminal M3-M2 on the DO-A3
card by the setting value for the multi-function digital output. This
parameter is enabled when F5-09 = 2 [DO-A3 Output Mode
Selection = 8 channel select(F5-01 to F5-08)].
V/f
CL-V/f
OLV
CLV
AOLV
Selects the function output from terminal M3-M4 on the DO-A3
card by the setting value for the multi-function digital output. This
parameter is enabled when F5-09 = 2 [DO-A3 Output Mode
Selection = 8 channel select(F5-01 to F5-08)].
V/f
CL-V/f
OLV
CLV
AOLV
Selects the output mode of signals output from the DO-A3 card.
0 : 8 channel individual
1 : Binary code output
2 : 8 channel select(F5-01 to F5-08)
YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manual
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Default
Ref.
(Range)
0
729
(0 - 1A7)
1
729
(0 - 1A7)
2
729
(0 - 1A7)
4
729
(0 - 1A7)
6
730
(0 - 1A7)
37
730
(0 - 1A7)
F
730
(0 - 1A7)
F
730
(0 - 1A7)
0
730
(0 - 2)

Advertisement

Table of Contents
loading

Table of Contents