10.10 H: Terminal Functions
No.
Name
(Hex.)
H6-07
Pulse Train
Monitor Scaling
(0432)
RUN
H6-08
Pulse Train Input
Min Frequency
(043F)

H7: Virtual Multi-Function I/O

No.
Name
(Hex.)
H7-00
Virtual MFIO
selection
(116F)
H7-01
Virtual Multi-
Function Input 1
(1185)
H7-02
Virtual Multi-
Function Input 2
(1186)
H7-03
Virtual Multi-
Function Input 3
(1187)
H7-04
Virtual Multi-
Function Input 4
(1188)
H7-10
Virtual Multi-
Function Output 1
(11A4)
H7-11
Virtual Output 1
Delay Time
(11A5)
H7-12
Virtual Multi-
Function Output 2
(11A6)
H7-13
Virtual Output 2
Delay Time
(11A7)
H7-14
Virtual Multi-
Function Output 3
(11A8)
H7-15
Virtual Output 3
Delay Time
(11A9)
H7-16
Virtual Multi-
Function Output 4
(11AA)
H7-17
Virtual Output 4
Delay Time
(11AB)
H7-30
Virtual Analog
Input Selection
(1177)
H7-31
Virtual Analog
Input Gain
(1178)
RUN
H7-32
Virtual Analog
Input Bias
(1179)
RUN
464
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the frequency of the pulse train output signal used when the
item selected with H6-06 [Pulse Train Monitor Selection] is output
at 100%.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the minimum frequency of the pulse train signal detectable by
terminal RP in units of 0.1 Hz.
Description
V/f
CL-V/f
OLV
CLV
AOLV
Enables or disables the virtual I/O function. If enable is not set, the
virtual I/O function will not operate.
0 : Disabled
1 : Enabled
V/f
CL-V/f
OLV
CLV
AOLV
Selects the function that enters the virtual input selected with the
H7-10 [Virtual Multi-Function Output 1].
V/f
CL-V/f
OLV
CLV
AOLV
Selects the function that enters the virtual input selected with the
H7-12 [Virtual Multi-Function Output 2].
V/f
CL-V/f
OLV
CLV
AOLV
Selects the function that enters the virtual input selected with H7-14
[Virtual Multi-Function Output 3].
V/f
CL-V/f
OLV
CLV
AOLV
Selects the function that enters the virtual input selected with the
H7-16 [Virtual Multi-Function Output 4].
V/f
CL-V/f
OLV
CLV
AOLV
Selects the function for virtual digital output 1.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the minimum ON time for virtual digital output 1.
V/f
CL-V/f
OLV
CLV
AOLV
Selects the function for virtual digital output 2.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the minimum ON time for virtual digital output 2.
V/f
CL-V/f
OLV
CLV
AOLV
Selects the function for virtual digital output 3.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the minimum ON time for virtual digital output 3.
V/f
CL-V/f
OLV
CLV
AOLV
Selects the function for virtual digital output 4.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the minimum ON time for virtual digital output 4.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the virtual analog input function.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the virtual analog input gain.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the virtual analog input bias.
YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manual
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Default
Ref.
(Range)
1440 Hz
822
(0 - 32000 Hz)
0.5 Hz
823
(0.1 - 1000.0 Hz)
Default
Ref.
(Range)
0
823
(0, 1)
F
824
(0 - 19F)
F
824
(0 - 19F)
F
824
(0 - 19F)
F
824
(0 - 19F)
F
824
(0 - 1A7)
0.1 s
824
(0.0 - 25.0 s)
F
824
(0 - 1A7)
0.1 s
825
(0.0 - 25.0 s)
F
825
(0 - 1A7)
0.1 s
825
(0.0 - 25.0 s)
F
825
(0 - 1A7)
0.1 s
825
(0.0 - 25.0 s)
F
825
(0 - 41)
100.0%
825
(-999.9 - 999.9%)
0.0%
825
(-999.9 - 999.9%)

Advertisement