11.11 o: Keypad-Related Settings
o5-04: Log Monitor Data 2
No.
Name
(Hex.)
o5-04
Log Monitor Data 2
(1554)
RUN
Note:
Select 101 to 855 [U1-01 to U8-55] to specify log data. For example, to display U1-05 [Motor Speed], set o5-08 = 105. Set the
parameter to 000 when you do not wish to select any data log monitors. U2 monitor [Fault Trace] and U3 Monitor [Fault History]
cannot be selected.
o5-05: Log Monitor Data 3
No.
Name
(Hex.)
o5-05
Log Monitor Data 3
(1555)
RUN
Note:
Select 101 to 855 [U1-01 to U8-55] to specify log data. For example, to display U1-05 [Motor Speed], set o5-08 = 105. Set the
parameter to 000 when you do not wish to select any data log monitors. U2 monitor [Fault Trace] and U3 Monitor [Fault History]
cannot be selected.
o5-06: Log Monitor Data 4
No.
Name
(Hex.)
o5-06
Log Monitor Data 4
(1556)
RUN
Note:
Select 101 to 855 [U1-01 to U8-55] to specify log data. For example, to display U1-05 [Motor Speed], set o5-08 = 105. Set the
parameter to 000 when you do not wish to select any data log monitors. U2 monitor [Fault Trace] and U3 Monitor [Fault History]
cannot be selected.
o5-07: Log Monitor Data 5
No.
Name
(Hex.)
o5-07
Log Monitor Data 5
(1557)
RUN
Note:
Select 101 to 855 [U1-01 to U8-55] to specify log data. For example, to display U1-05 [Motor Speed], set o5-08 = 105. Set the
parameter to 000 when you do not wish to select any data log monitors. U2 monitor [Fault Trace] and U3 Monitor [Fault History]
cannot be selected.
o5-08: Log Monitor Data 6
No.
Name
(Hex.)
o5-08
Log Monitor Data 6
(1558)
RUN
Note:
Select 101 to 855 [U1-01 to U8-55] to specify log data. For example, to display U1-05 [Motor Speed], set o5-08 = 105. Set the
parameter to 000 when you do not wish to select any data log monitors. U2 monitor [Fault Trace] and U3 Monitor [Fault History]
cannot be selected.
914
V/f
CL-V/f
OLV
CLV
AOLV
Configures the data log monitor. This parameter is only enabled for LED
keypads.
V/f
CL-V/f
OLV
CLV
AOLV
Configures the data log monitor. This parameter is only enabled for LED
keypads.
V/f
CL-V/f
OLV
CLV
AOLV
Configures the data log monitor. This parameter is only enabled for LED
keypads.
V/f
CL-V/f
OLV
CLV
AOLV
Configures the data log monitor. This parameter is only enabled for LED
keypads.
V/f
CL-V/f
OLV
CLV
AOLV
Configures the data log monitor. This parameter is only enabled for LED
keypads.
YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manual
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Default Setting
(Setting Range)
102
(000,101 - 855)
Default Setting
(Setting Range)
103
(000,101 - 855)
Default Setting
(Setting Range)
107
(000,101 - 855)
Default Setting
(Setting Range)
108
(000,101 - 855)
Default Setting
(Setting Range)
000
(000,101 - 855)