10.5 b: Application
No.
Name
(Hex.)
b2-03
DC Inject Braking
Time at Start
(018B)
b2-04
DC Inject Braking
Time at Stop
(018C)
b2-08
Magnetic Flux
Compensation
(0190)
Value
b2-12
Short Circuit Brake
Time @ Start
(01BA)
b2-13
Short Circuit Brake
Time @ Start
(01BB)
b2-18
Short Circuit
Braking Current
(0177)

b3: Speed Search

No.
Name
(Hex.)
b3-01
Speed Search
Selection at Start
(0191)
b3-02
Speed Search
Deactivation
(0192)
Current
b3-03
Speed Search
Deceleration Time Determines the deceleration time during Speed Search operation.
(0193)
b3-04
V/f Gain during
Speed Search
(0194)
b3-05
Speed Search
Delay Time
(0195)
b3-06
Speed Estimation
Current Level 1
(0196)
b3-07
Speed Estimation
Current Level 2
(0197)
402
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the DC Inject Braking Time at start. Configures the zero speed
control at start when using Closed Loop Vector Control, Advanced
Open Loop Vector Control, or Closed Loop Vector Control for PM.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the DC Inject Braking Time at stop. Configures the zero speed
control at stop when using Closed Loop Vector Control, Advanced
Open Loop Vector Control, or Closed Loop Vector Control for PM.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the amount of current injected in the beginning of DC Injection
Braking at start (initial excitation) as a percentage of the value set in
E2-03 [Motor No-Load Current].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the Short Circuit Braking time at start.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the Short Circuit Braking time at stop.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the Short Circuit Braking current as a percentage of the motor
rated current.
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets whether to execute Speed Search or not with each Run
command.
0 : Disabled
1 : Enabled
V/f
CL-V/f
OLV
CLV
AOLV
Sets the current level that ends Speed Search as a percentage of the
drive rated output current. Normally there is no need to change this
setting.
V/f
CL-V/f
OLV
CLV
AOLV
Set the time it takes to decelerate from the maximum output
frequency to the minimum output frequency.
V/f
CL-V/f
OLV
CLV
AOLV
Configures the ratio used to reduce the V/f during searches to reduce
the output current during speed searches.
V/f
CL-V/f
OLV
CLV
AOLV
If a magnetic contactor is installed between the drive and the motor,
this parameter sets a delay time to activate the magnetic contactor
by delaying Speed Search.
V/f
CL-V/f
OLV
CLV
AOLV
Configure the amount of current that flows to the motor as a
coefficient of the motor rated current when executing the Speed
Estimation Speed Search. Normally there is no need to change this
setting.
V/f
CL-V/f
OLV
CLV
AOLV
The amount of current that flows to the motor when Speed
Estimation Speed Searches are executed is configured as a
coefficient of E2-03 [Motor No-Load Current] or E4-03 [Motor 2
Rated No-Load Current]. Normally there is no need to change this
setting.
YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manual
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Default Setting
Ref.
(Range)
A1-02 = 4: 0.03 s
605
Other than A1-02 =
4: 0.00 s
(0.00 - 10.00 s)
Determined by A1-
606
02
(0.00 - 10.00 s)
0%
606
(0 - 1000%)
0.00 s
606
(0.00 - 25.50 s)
A1-02 = 8: 0.00 s
607
Other than A1-02 =
8: 0.50 s
(0.00 - 25.50 s)
100.0%
607
(0.0 - 200.0%)
Default
Ref.
(Range)
Determined by A1-
610
02
(0, 1)
Determined by A1-
611
02
(0 - 200%)
2.0 s
611
(0.1 - 10.0 s)
Determined by o2-
611
04
(10 - 100)
0.2 s
611
(0.0 - 100.0 s)
Determined by o2-
611
04
(0.0 - 2.0)
1.0
612
(0.0 - 3.0)

Advertisement