11.8 H: Terminal Functions
1C: Motor 2 Selection
Setting
Function
1C
Motor 2 Selection
ON : Motor 2 Selection
OFF : Motor 1 Selection
1D: During Regeneration
Setting
Function
1D
During Regeneration
ON : Motor is regenerating.
OFF : Motor is operating or stopped.
1E: Restart Enabled
Setting
Function
1E
Restart Enabled
The terminal turns off when a fault is automatically reset by the Auto Restart function. The terminal turns off
when the Auto Restart function detects the fault again since Auto Restart function cannot function any longer due
to number of attempts set with L5-01 [Number of Auto Restart Attempts] being reached.
Note:
Refer to "L5: Fault Restart" for more information.
1F: Motor Overload Alarm (oL1)
Setting
Function
1F
Motor Overload
Alarm (oL1)
Note:
Refer to "L1-01: Motor Overload Protection Select" for more information.
20: Drive Overheat Pre-Alarm (oH)
Setting
Function
20
Drive Overheat Pre-
Alarm (oH)
Note:
Refer to "L8-02: Overheat Alarm Level" for more information.
21: EDM
Setting
Function
21
EDM
Note:
EDM = External Device Monitor
ON : Safety stop state
Both terminal H1-HC and H2-HC have been turned off, or released (safety stop state).
OFF : Safety circuit fault or RUN/READY
794
V/f
CL-V/f
OLV
CLV
AOLV
The terminal turns on when motor 2 is selected.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal turns on when the motor is regenerating.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal turns on when a fault that can be restarted occurs and the Auto Restart function is
attempting to operate.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal turns on when the electronic thermal protector value of the motor overload protective
function reaches at least 90% of the detection level.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal turns on when the drive heatsink temperature reaches the level set with L8-02
[Overheat Alarm Level].
V/f
CL-V/f
OLV
CLV
AOLV
The terminal turns on (safety stop state) when the safety circuit and safety diagnosis circuit is not
experiencing a failure and when both terminals H1-HC and H2-HC are off (released).
YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manual
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
Description
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV