U1-09
Torque Reference
(0048)
U1-10
Input Terminal
Status
(0049)
U1-11
Output Terminal
Status
(004A)
U1-12
Drive Status
(004B)
U1-13
Terminal A1 Input
Lv
(004E)
U1-14
Terminal A2 Input
Lv
(004F)
U1-15
Terminal A3 Input
Lv
(0050)
U1-16
Output Freq
afterSFS
(0053)
YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manual
Description
V/f
CL-V/f
OLV
CLV
AOLV
Displays the internal torque reference value.
Unit: 0.1%
V/f
CL-V/f
OLV
CLV
AOLV
Displays the status of the multi-function input terminal using 1 (ON)
and 0 (OFF).
For example, U1-10 = 00000011 is displayed when terminals S1
and S2 are ON.
bit 0 : Terminal S1 (MFDI 1)
bit 1 : Terminal S2 (MFDI 2)
bit 2 : Terminal S3 (MFDI 3)
bit 3 : Terminal S4 (MFDI 4)
bit 4 : Terminal S5 (MFDI 5)
bit 5 : Terminal S6 (MFDI 6)
bit 6 : Terminal S7 (MFDI 7)
bit 7 : Terminal S8 (MFDI 8)
V/f
CL-V/f
OLV
CLV
AOLV
Displays the status of the multi-function output terminal using 1
(ON) and 0 (OFF).
For example, U1-11 = 00000011 is displayed when terminals M1
and M3 are ON.
bit 0 : Terminals M1-M2
bit 1 : Terminals M3-M4
bit 2 : Terminals P1-C1
bit 3 : Terminals P2-C2
bit 4 : Not used (normal value of 0).
bit 5 : Not used (normal value of 0).
bit 6 : Not used (normal value of 0).
bit 7 : Fault relay MA/MB-MC
V/f
CL-V/f
OLV
CLV
AOLV
Displays the drive status using 1 (ON) and 0 (OFF).
For example, U1-12 = 00000101 is displayed during run with the
Reverse run command.
bit 0 : During run
bit 1 : During zero-speed
bit 2 : During reverse
bit 3 : During fault reset signal input
bit 4 : During speed agreement
bit 5 : Drive ready
bit 6 : During minor fault detection
bit 7 : During fault detection
V/f
CL-V/f
OLV
CLV
AOLV
Displays the signal level of terminal A1.
Unit: 0.1%
V/f
CL-V/f
OLV
CLV
AOLV
Displays the signal level of terminal A2.
Unit: 0.1%
V/f
CL-V/f
OLV
CLV
AOLV
Displays the signal level of terminal A3.
Unit: 0.1%
V/f
CL-V/f
OLV
CLV
AOLV
Displays the output frequency after soft start. Displays the
frequency with acceleration and deceleration times and S-curves.
Display units are determined by o1-03 [Keypad Display Selection].
Unit: 0.01 Hz
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
10.17 U: Monitors
MFAO Signal
Ref.
Level
10 V = Motor rated
-
torque (-10 V to
+10 V)
No signal output
-
available
No signal output
-
available
No signal output
-
available
10 V = 100% (-10
-
V to +10 V)
10 V = 100% (-10
-
V to +10 V)
0 V = 100% (-10 V
-
to +10 V)
10 V = Max.
-
frequency (-10 V
to +10 V)
497
10

Advertisement

Table of Contents
loading

Table of Contents