YASKAWA GA700 Technical Manual page 920

High performance type; 200 v class: 0.4 to 110 kw; 400 v class: 0.4 to 355 kw
Hide thumbs Also See for GA700:
Table of Contents

Advertisement

11.12 T: Auto-Tuning
T2-04: PM Motor Rated Power
No.
Name
(Hex.)
T2-04
PM Motor Rated
Power
(0730)
Note:
Capacities 300 kW and less are set in units of 0.01 kW. Capacities above 300 kW are set in units of 0.1 kW. The maximum applicable
motor output varies depending on the setting of C6-01 [Normal / Heavy Duty Selection].
T2-05: PM Motor Rated Voltage
No.
Name
(Hex.)
T2-05
PM Motor Rated
Voltage
(0732)
T2-06: PM Motor Rated Current
No.
Name
(Hex.)
T2-06
PM Motor Rated
Current
(0733)
T2-07: PM Motor Base Frequency
No.
Name
(Hex.)
T2-07
PM Motor Base
Frequency
(0753)
T2-08: Number of PM Motor Poles
No.
Name
(Hex.)
T2-08
Number of PM Motor
Poles
(0734)
T2-09: PM Motor Base Speed
No.
Name
(Hex.)
T2-09
PM Motor Base
Speed
(0731)
T2-10: PM Motor Stator Resistance
No.
Name
(Hex.)
T2-10
PM Motor Stator
Resistance
(0754)
Note:
Do not confuse this parameter with line-to-line resistance.
920
V/f
CL-V/f
OLV
CLV
AOLV
Sets the rated output power (kW) of a PM motor.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the rated voltage (V) of the motor.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the rated current (A) of the motor.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the base frequency of the motor (Hz).
V/f
CL-V/f
OLV
CLV
AOLV
Sets the number of motor poles.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the motor base speed (min
V/f
CL-V/f
OLV
CLV
AOLV
Sets the stator resistance per phase of the motor.
YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manual
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
Description
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
-1
(r/min)).
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Default Setting
(Range)
Determined by o2-04
and C6-01
(0.00 - 650.00 kW)
Default Setting
(Range)
200 V Class: 200.0 V,
400 V Class: 400.0 V
(200 V Class: 0.0 -
255.0 V, 400 V Class:
0.0 - 510.0 V)
Default Setting
(Range)
Determined by o2-04
(10% to 200% of the
drive rated current)
Default Setting
(Range)
87.5 Hz
(0.0 - 590.0 Hz)
Default Setting
(Range)
6
(2 - 48)
Default Setting
(Range)
1750 min
-1
(r/min)
(0 - 34500 min
-1
(r/
min))
Default Setting
(Range)
Determined by T2-02
(0.000 - 65.000 Ω)

Advertisement