11.5 d: Reference Settings
Note:
• When setting Jump Frequency 1 through 3, make sure that the parameters do not overlap.
• The frequency reference changes automatically when the drive is within the range of the Jump frequency. When Jump is executed, the
output frequency does not change suddenly but changes smoothly according to the values set in C1-01 [Acceleration Time 1] and C1-
02 [Deceleration Time 1].
d3-01: Jump Frequency 1
No.
Name
(Hex.)
d3-01
Jump Frequency 1
(0294)
Note:
Set this parameter to 0.0 Hz to disable the Jump frequency.
d3-02: Jump Frequency 2
No.
Name
(Hex.)
d3-02
Jump Frequency 2
(0295)
Note:
Set this parameter to 0.0 Hz to disable the Jump frequency.
d3-03: Jump Frequency 3
No.
Name
(Hex.)
d3-03
Jump Frequency 3
(0296)
Note:
Set this parameter to 0.0 Hz to disable the Jump frequency.
d3-04: Jump Frequency Width
No.
Name
(Hex.)
d3-04
Jump Frequency
Width
(0297)
676
Figure 11.59 Jump Frequency
V/f
CL-V/f
OLV
CLV
AOLV
Sets the median value of the specific frequency band that needs to be
jumped.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the median value of the specific frequency band that needs to be
jumped.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the median value of the specific frequency band that needs to be
jumped.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the width of a specific frequency band that needs to be jumped.
YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manual
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Default
(Range)
0.0 Hz
(Determined by A1-
02)
Default
(Range)
0.0 Hz
(Determined by A1-
02)
Default
(Range)
0.0 Hz
(Determined by A1-
02)
Default
(Range)
1.0 Hz
(Determined by A1-
02)