Setting
Function
68
High Slip Braking
(HSB)
6A
Drive Enable
71
Speed/Torque
Control Switch
72
Zero Servo
75
Up 2 Command
76
Down 2 Command
77
ASR Gain Switch
78
Ex.Torque Ref
Polarity Inversion
7A
KEB Ride-Thru 2
(N.C.)
7B
KEB Ride-Thru 2
(N.O.)
7C
Short Circuit
Braking (N.O.)
7D
Short Circuit
Braking (N.C.)
YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manual
V/f
CL-V/f
OLV
CLV
AOLV
Stops the motor using high-slip braking.
V/f
CL-V/f
OLV
CLV
AOLV
The keypad displays dnE [Drive Enabled] when the terminal is turned OFF and the Run
command will not be accepted.
V/f
CL-V/f
OLV
CLV
AOLV
Switches between torque and speed control.
ON : Torque control
OFF : Speed control
V/f
CL-V/f
OLV
CLV
AOLV
Holds the motor when it is stopped.
V/f
CL-V/f
OLV
CLV
AOLV
Accelerates the motor by increasing the frequency reference bias value when the terminal
is turned ON. Always set the Up2 command and Down 2 command as a pair.
Note:
When the Up2/Down2 function is used, set the optimal bias limit value using d4-08
and d4-09 [Up/Down 2 Bias Upper Limit/Lower Limit (Up/Down 2)].
V/f
CL-V/f
OLV
CLV
AOLV
Decelerates the motor by reducing the frequency reference bias value when the terminal
is turned ON. Always set the Up2 command and Down 2 command as a pair.
Note:
When the Up2/Down2 function is used, set the optimal bias limit value using d4-08
and d4-09 [Up/Down 2 Bias Upper Limit/Lower Limit (Up/Down 2)].
V/f
CL-V/f
OLV
CLV
AOLV
Switches the ASR proportional gain set in C5-01 [ASR Proportional Gain 1] and C5-03
[ASR Proportional Gain 1/2].
ON : C5-03
OFF : C5-01
V/f
CL-V/f
OLV
CLV
AOLV
Switches the rotation direction of the external torque reference.
ON : External torque reference reverse direction
OFF : External torque reference forward direction
V/f
CL-V/f
OLV
CLV
AOLV
Switches the KEB 2 Ride-Thru function between enable and disable via the KEB Ride-
Thru 2 (N.C.).
ON : Normal operation
OFF : Deceleration during momentary power loss
V/f
CL-V/f
OLV
CLV
AOLV
Switches the KEB 2 Ride-Thru function between enable and disable via the KEB Ride-
Thru 2 (N.O.).
ON : Deceleration during momentary power loss
OFF : Normal operation
V/f
CL-V/f
OLV
CLV
AOLV
Enables and disables Short Circuit Braking. (N.O.)
ON : Short Circuit Braking is enabled.
OFF : Normal operation
Note:
This function enables only when the PM motor is used for A1-02 = 8 [Control Method
Selection = EZ Open Loop Vector Control].
V/f
CL-V/f
OLV
CLV
AOLV
Enables and disables Short Circuit Braking. (N.C.)
ON : Normal operation
OFF : Short Circuit Braking is enabled.
Note:
This function enables only when the PM motor is used for A1-02 = 8 [Control Method
Selection = EZ Open Loop Vector Control].
Description
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
10.10 H: Terminal Functions
Ref.
771
771
771
772
772
774
774
774
775
775
775
775
10
449

Advertisement

Table of Contents
loading

Table of Contents