T2: Pm Motor Auto-Tuning - YASKAWA GA700 Technical Manual

High performance type; 200 v class: 0.4 to 110 kw; 400 v class: 0.4 to 355 kw
Hide thumbs Also See for GA700:
Table of Contents

Advertisement

No.
Name
(Hex.)
T1-10
Motor Rated Slip
(070A)
T1-11
Motor Iron Loss
(070B)

T2: PM Motor Auto-Tuning

No.
Name
(Hex.)
T2-01
PM Motor Auto-
Tuning Mode
(0750)
Select
T2-02
PM Motor Code
Selection
(0751)
T2-03
PM Motor Type
(0752)
T2-04
PM Motor Rated
Power
(0730)
T2-05
PM Motor Rated
Voltage
(0732)
T2-06
PM Motor Rated
Current
(0733)
T2-07
PM Motor Base
Frequency
(0753)
T2-08
Number of PM
Motor Poles
(0734)
T2-09
PM Motor Base
Speed
(0731)
T2-10
PM Motor Stator
Resistance
(0754)
T2-11
PM Motor d-Axis
Inductance
(0735)
T2-12
PM Motor q-Axis
Inductance
(0736)
YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manual
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the motor rated slip.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the iron loss information for determining the energy-saving
coefficient.
Description
V/f
CL-V/f
OLV
CLV
AOLV
Selects the type of Auto-Tuning for PM motors to be used.
0 : PM Motor Parameter Settings
1 : PM Stationary Auto-Tuning
2 : PM StaTun for Stator Resistance
3 : Z Pulse Offset Tuning
4 : PM Rotational Auto-Tuning
V/f
CL-V/f
OLV
CLV
AOLV
If the drive is operating a Yaskawa PM motor from the SMRA,
SSR1, or SST4 series, enter the PM motor code in accordance with
the rotation speed and motor output.
V/f
CL-V/f
OLV
CLV
AOLV
Selects the type of PM motor the drive will operate.
0 : IPM Motor
1 : SPM Motor
V/f
CL-V/f
OLV
CLV
AOLV
Sets the rated output power (kW) of a PM motor.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the rated voltage (V) of the motor.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the rated current (A) of the motor.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the base frequency of the motor (Hz).
V/f
CL-V/f
OLV
CLV
AOLV
Sets the number of motor poles.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the motor base speed (min
V/f
CL-V/f
OLV
CLV
AOLV
Sets the stator resistance per phase of the motor.
Note:
Do not confuse this parameter with line-to-line resistance.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the d-Axis inductance of the motor on a per phase basis.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the q-Axis inductance of the motor on a per phase basis.
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
-1
(r/min)).
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
10.16 T: Motor Tuning
Default
Ref.
(Range)
-
918
(0.00 - 20.00 Hz)
Determined by E2-
918
11 or E4-11
(0 - 65535 W)
Default
Ref.
(Range)
0
919
(Determined by
A1-02)
Determined by A1-
919
02 and o2-04
(0000 - FFFF)
1
919
(0, 1)
Determined by o2-
920
04 and C6-01
(0.00 - 650.00 kW)
200 V Class: 200.0
920
V, 400 V Class:
400.0 V
(200 V Class: 0.0 -
255.0 V, 400 V
Class: 0.0 - 510.0
V)
Determined by o2-
920
04
(10% to 200% of
the drive rated
current)
87.5 Hz
920
(0.0 - 590.0 Hz)
6
920
(2 - 48)
-1
1750 min
(r/min)
920
-1
(0 - 34500 min
(r/
min))
Determined by T2-
920
02
(0.000 - 65.000 Ω)
Determined by T2-
921
02
(0.00 - 600.00 mH)
Determined by T2-
921
02
(0.00 - 600.00 mH)
493
10

Advertisement

Table of Contents
loading

Table of Contents