YASKAWA GA700 Technical Manual page 900

High performance type; 200 v class: 0.4 to 110 kw; 400 v class: 0.4 to 355 kw
Hide thumbs Also See for GA700:
Table of Contents

Advertisement

11.11 o: Keypad-Related Settings
Note:
Before configuring o1-10 and o1-11, configure o1-03 = 3 [Keypad Display Selection = User-selected units].
o1-11: User-SetDisplayUnits Dec Display
No.
Name
(Hex.)
o1-11
User-SetDisplayUnits
Dec Display
(0521)
0 : No Dec (XXXXX)
1 : 1 Dec (XXXX.X)
2 : 2 Dec (XXX.XX)
3 : 3 Dec (XX.XXX)
Note:
Before configuring o1-10 [User-Set Display Units Max Value] and o1-11, set o1-03 = 3 [Keypad Display Selection = User-selected
units].
o1-24 to o1-35: 1st to 12th Monitor Settings
No.
Name
(Hex.)
o1-24 to o1-
1st to 12th Monitor
35
Settings
(11AD to
11B8)
RUN
Monitor items selected by the LCD keypad [User Monitors] are stored in these parameters.
Note:
• Up to three selected monitors can be displayed on one LCD keypad screen.
–If only one monitor is selected, this monitor appears enlarged. For example, when o1-25 through o1-35 = 000, the monitor selected
with o1-24 appears enlarged.
–If only two monitors are selected, these monitors appear enlarged.
–When 4 or more monitors are selected, the fourth and subsequent monitors appear on subsequent screens.
• Monitors selected with o1-24 through o1-26 can be displayed as bar graphs or analog meters.
–Bar graph display: Up to 3 maximum
Select with o1-24, o1-25, and o1-26.
–Analog meter display: 1
Select with o1-24.
o1-36: LCD backlight adjustment
No.
Name
(Hex.)
o1-36
LCD backlight
adjustment
(11B9)
RUN
Reducing the setting value lowers the brightness of the backlight. Increasing the setting value increases the
brightness.
o1-37: LCD backlight ON/OFF Selection
No.
Name
(Hex.)
o1-37
LCD backlight ON/
OFF Selection
(11BA)
RUN
Note:
The brightness of the LCD backlight is adjusted with o1-36 [LCD backlight adjustment].
900
V/f
CL-V/f
OLV
CLV
AOLV
Configures the number of decimal places for frequency reference and
monitor values.
V/f
CL-V/f
OLV
CLV
AOLV
Up to a maximum of 12 desired monitors can be selected as user monitors.
This parameter is only enabled for LED keypads.
V/f
CL-V/f
OLV
CLV
AOLV
Configures the brightness of the LCD keypad backlight.
V/f
CL-V/f
OLV
CLV
AOLV
Selects the operation of the LCD backlight automatic shut off function.
YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manual
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Default Setting
(Setting Range)
Determined by o1-03
(0 - 3)
Default Setting
(Setting Range)
o1-24: 101
o1-25: 102
o1-26: 103
o1-27 to o1-35: 000
(000, 101 - 825)
Default Setting
(Setting Range)
3
(1 - 5)
Default Setting
(Setting Range)
1
(0, 1)